Pluto Status Monitor
Portable, cross-platform desktop utility for Windows 64-bit, macOS Apple Silicon and macOS Intel, written to quickly check the status of your ADALM-Pluto SDR: connection, TRX/FPGA temperatures, real-time historical graph, RF status, CPU load, free RAM, RX/TX LO frequencies, configured clock source and technical snapshot.
Pluto Status Monitor was born from a real station need: when the Pluto sits on the roof, inside a remote box or simply far from the shack, you want to understand in a few seconds whether everything is really ready to work, without opening ten different tools.
Over time the program has been heavily cleaned up and re-engineered, removing misleading indicators and keeping only the data that are truly useful. In particular, the old “clock stability” area has been replaced by a more coherent readout of the configured clock source, while the main graph is now dedicated to real temperatures.
Important note: with F5OEO firmware and the Pluto running in USB mode, SSH access from Pluto Status Monitor may fail; a USB → Ethernet adapter fixes the issue at the root. With stock ADI firmware (0.37, 0.38, 0.39) this problem usually does not occur. For quick “sure shot” diagnostics, also see PlutoProbe.
Pluto Status Monitor is one of the software tools I also use with the Groundstation DeLuxe for QO-100, where the Pluto SDR is the centre of the station and a quick check of the unit’s real status becomes part of the operating workflow.
The current release aims to be clearer and more useful in a real station: Dark/Light themes, visible clock configuration in “My Pluto”, configurable logging and a TRX + FPGA temperature graph as a real operational reference.
What is it for in real life?
In a nutshell: it tells you right away whether your Pluto is “ready” before you start operating, especially when it is remote (roof / box / VPN).
Read more ↓- Current release: v2.0.02
- Distribution: separate portable ZIP packages by platform
- Supported platforms: Windows 10/11 (64-bit), macOS 12 Monterey or newer
- Plutos tested: ADI Pluto Rev.C/D, Hamgeek Pluto+
- Firmwares tested: ADI 0.37 / 0.38 / 0.39, F5OEO, Pluto+
- Connection to Pluto: SSH / libiio depending on the feature used
Main window: connection state, instant temperatures, CPU, RAM, RX/TX LO, ENSM mode and TRX/FPGA temperature graph over time. The GUI remains substantially aligned between Windows and macOS, apart from the normal native differences of the two platforms.
Note for release v2.0.02: this public release keeps the same version number and the same features across Windows 64-bit, macOS Apple Silicon and macOS Intel, with differences only related to the native behavior of each platform.
What’s new in the current release
Cleaner interface
- New Dark Mode and Light Mode themes, with aligned behavior between Windows and macOS.
- Better visual consistency across windows, buttons and dialogs on the supported platforms.
- A cleaner experience during long monitoring sessions.
A more useful “My Pluto” window
- New Clock Configuration section.
- Displays the clock source as configured in firmware.
- A clearer and more coherent message for users running GPSDOs or external references.
More concrete monitoring
- Main graph now dedicated to TRX + FPGA temperatures.
- Expanded RF Status and more relevant operational data.
- More focus on what really matters during actual use.
Diagnostics and management
- Logging applicativo configurabile da INI.
- Base dati via libiio per diverse letture della nuova generazione 2.x.
- Prima release pubblica multipiattaforma con pacchetti distinti per Win64, macOS ARM e macOS Intel.
What it is for in practice
Pluto Status Monitor answers one very simple but fundamental question: “Is my Pluto really ready to work?” If the Pluto is inside a remote box, on the roof or simply far from the shack, you need a fast and reliable check of the critical parameters.
The program collects and presents in a clear way the information that is most useful for day-to-day operation: device reachability, connection state, temperatures, CPU load, RAM, LO frequencies, ENSM state, firmware and a technical Pluto snapshot.
The clock-related area has been deliberately brought back to what the software can state in a coherent way: the configured clock source. It is no longer presented as a physical measurement of stability or of the actual presence of an external reference, but as useful and correct diagnostic information.
What it does
1) Checks Pluto presence and status
- Attempts Pluto detection over the network (with resilient retry handling).
- Connected/offline distinction and clear indication in the GUI / status bar.
- Practical use: quick check before opening SDR Console or starting a full remote session.
2) Temperature graph over time
- The main graph shows TRX + FPGA over the last minutes, no longer the presumed clock deviation.
- Automatic Y scale: useful both in winter and in warm / ventilated boxes.
- Real data, readable at a glance and genuinely useful in operation.
3) TRX / FPGA temperatures with configurable thresholds
- TRX and FPGA temperature readout with stable GUI-side presentation.
- Fast visual indicators (soft gradient or hard transition, selectable from the menu).
- Attention / critical / dangerous messages and configurable thresholds.
4) “My Pluto” window (technical snapshot)
- Identity, firmware, current state, RF Status and system data in a dedicated window.
- Report copyable to the clipboard for debugging and quick sharing.
What it does NOT do (by design)
Let me be very clear from the start: Pluto Status Monitor is not an SDR “super suite”. It is a practical monitoring / quick-diagnostics tool. That is what it does, and it tries to do it well.
- It is not an RX/TX SDR application (it does not replace SDR Console, etc.).
- It does not handle QSOs, logging, satellite tracking or full operating functions.
- Non controlla PTT, PA, rotori, sequencer o altre periferiche di stazione.
- It does not update Pluto firmware.
- It does not “repair” wrong Pluto configurations by itself.
- It does not promise a real measurement of clock stability when the firmware does not actually expose one.
- It is not meant to cover every possible system combination outside the declared scope: Win64 + macOS ARM/Intel in this release, Linux in the future.
- No “impossible” requests 😄
Minimum requirements (current release)
- Windows: 10 / 11 (64-bit).
- macOS: 12 Monterey or newer for full functionality.
- Working network reachability to the Pluto (LAN/VPN/remote LAN already in place).
- Pluto SSH credentials (root / analog or custom).
- A user-writable folder or equivalent location for configuration and local program files.
- ADI Pluto Rev.C/D and Hamgeek Pluto+ tested with ADI 0.37 / 0.38 / 0.39, F5OEO and Pluto+ firmware.
“Portable” distribution (ZIP)
The program is distributed as separate ZIP packages by platform: EXE + auxiliary files on Windows, self-contained .app bundle on macOS. No classic installer, no wizard.
- To use it: unzip the package wherever you prefer.
- On Windows: launch the executable and, if you like, create a desktop shortcut.
- On macOS: copy the app wherever you prefer and follow the initial Gatekeeper notes.
- Uninstall: remove the shortcut + program folder, or drag the app to the Trash. Done.
How to use it in 3 minutes
- 1Download the correct package for your platform and unzip it into a writable folder, or on macOS copy the app to the desired location.
- 2Launch the program. On macOS, at first start you may need to authorize it through Gatekeeper. Then verify the Pluto IP, user, password and SSH port in the Configuration window.
- 3Set the refresh interval to suit your needs (typically 1 s works well for live monitoring).
- 4In the Temperatures tab, adapt the thresholds to your real enclosure/cooling setup.
- 5Choose from the menu the temperature indicator style you prefer: soft gradient or hard transition.
- 6Use the main window + “My Pluto” for a quick check before/during operation.
Note: in the 2.x releases the configuration is leaner and more coherent with real station use; less reliable or redundant parts have been removed or scaled back.
Mini visual guide (clean and easy to browse)
Configuration: what to change for real (and what not to touch)
- Pluto IP (obvious, but this is where everyone trips when they change network/VPN).
- SSH credentials (Pluto default: root / analog if you did not change them).
- SSH port (default: 22; if your remote network uses a different port, you must enter it correctly here).
- Refresh interval (1 s is a good compromise for live use).
If these parameters are correct, the rest usually “falls into place”.
- Separate TRX / FPGA thresholds.
- Graph length configurable in minutes.
- Adapt them to your box (fans, season, sun exposure, etc.).
- Thresholds that are too tight = constant warnings = you lose the usefulness of monitoring.
Languages and customization
The program is ready to use in IT/EN and can also load external language files from the /languages folder (e.g. German, French, Spanish). In practice, you just edit a text file with any basic editor.
Download Pluto Status Monitor
The current v2.0.02 release is distributed in three separate packages, with the same version number and the same features across all supported platforms.
macOS note: at first launch the system may block the app because it is not signed/notarized. I prepared a dedicated note to help Mac users handle Gatekeeper on their own without going mad.
Documentation:
- User Manual (PDF, EN)
- macOS Installation Notes (PDF, EN)
- Manuale Utente (PDF, IT)
- Note di installazione macOS (PDF, IT)
Linux remains in the future plans. For now, the official public release is aligned across Windows 64-bit, macOS Apple Silicon and macOS Intel.
Free to use. If it helps you, buy me a coffee ☕
The program is free and openly downloadable. If it is useful to you and you would like to encourage me to keep it moving forward with improvements and new features, you can buy me a coffee via PayPal. No obligation, no pressure.
In short:If it fits well with the way you work, great. If your needs are different, it may simply not be the right program for you.
Useful feedback: if you encounter a real malfunction and want to report it, the most valuable contribution is feedback that is clear, concrete and repeatable: what you were doing, what happened and how I can reproduce the issue. Local modifications, customizations or very specific needs may instead lead to behaviors that fall outside the normally expected scenario.
Note about antivirus / SmartScreen
As can happen with self-produced Windows executables, some antivirus products or Windows SmartScreen itself may report false positives or display precautionary warnings. This is not a guarantee that it will happen, but it is correct to say it upfront. If in doubt, always download from the official link on this website of mine.
In particular, remember that Windows 10/11 may block the execution of programs downloaded from the Internet the first time: you have to tell it to proceed. On macOS, the equivalent logic is Gatekeeper and it is explained in the dedicated PDF note.
Declared compatibility and limits
- Most in-depth tests were carried out mainly on the original ADI Pluto Rev.C/D.
- Successful tests were also reported by users on the Hamgeek Pluto+.
- Verified firmwares: ADI 0.37 / 0.38 / 0.39, F5OEO, Pluto+.
- Non-standard setups: support not guaranteed (best effort, not enterprise helpdesk).
- Current release = stable on Win64, macOS Apple Silicon and macOS Intel.
Changelog
v2.0.02 Unified public release for Windows 64-bit, macOS Apple Silicon & macOS Intel
- Unified public release: same version number and same features across Windows 64-bit, macOS Apple Silicon and macOS Intel.
- New data acquisition via libiio, with faster and more robust readings than traditional textual parsing.
- RF monitoring expanded with new operating parameters, including RX/TX Bandwidth, RX AGC mode and RX/TX port selection, in addition to the extended RF Status section in the “My Pluto” window.
- Introduced Dark Mode and Light Mode themes, with a cleaned-up and coherent graphics pipeline across the supported platforms.
- Added to the “My Pluto” window the new Clock Configuration section, which clearly shows the clock source configured in firmware.
- Improved the overall responsiveness of the interface during window opening, refresh and data updates.
- Added the possibility to configure application logging from the INI file, while keeping
--debugmode as the top priority. - Introduced session CSV export to make data collection and diagnostics easier.
- Published macOS packages with a dedicated note about Gatekeeper, compatibility and first launch.
v1.1.00 2026-03-31
- Introduced the new temperature graph.
- Improved compatibility with F5OEO firmware.
- Added the possibility to configure the SSH port.
- Updated the main window with new operational information.
- Extended the “My Pluto” window with the new RF Status section.
- Included Italian and English user manuals in the package.
v1.0.33 2026-03-19
- Added automatic update checking at startup.
- Possibility to enable or disable update checking from the configuration.
- Added free RAM, RX LO and TX LO to the main window.
- Improved disconnection detection.
v1.0.31 2026-03-01
- Completed the OOP refactoring of the program.
- Added minimum and maximum TRX and FPGA temperatures to the “My Pluto” window.